Plant Data
Dam:
Type: ravity concrete dam with rock cover on air
suface; limited scoring possible
Crest length: 47,0 m
Height: 7,20 m and 6.0 m at spillway section
Spillway length: 6,00 m
Foundation depth: 2,00 m
Crest width: 1,60 m
Foundation width: 4,60 m
Stilling basin length: 7,40 m
Scoure gate: 1,50 x 1,50 m (wxh), invert level 2,0
m below spillway crest
Reservoir:
Length: 120 m
Width: 40 m
Depth: 2,5 m after scouring
Intake building:
Dip board: wooden plan
Rack: fine screen 1,65 x 2,68 cm (w x h), 60°
inclined
Rack cleaner: mechanical cleaner, manual or time
based operation
Power Conduit:
Type: conventionally excavated tunnel
Profile: inverted U-shapeHeight: 140 cm
Bottom width: 90 cm
Inclination: hydraulic minimum
Lining: partly concrete, partly cement plaster
Length: 194 m
Surge Tank:
Type: vertical shaft
Cross section: square
Penstock:
Type: steel pipe
Length: 181 m
Dimension: 740/11,4 mm
Bifurcation: 740/11,4 to 2 x 530/8 mm
Generation Set 1:
Type: Francis spiral turbine
Manufacturer: Weipert & Söhne, Stockerau
Year: 1923, refurbished in 1949 and 2001
Nominal Power: 100 kW at 53.5 m head and at
200 l/s flow
Generation Set 2:
Type: Francis spiral turbine
Manufacturer: CKD Turbo Technics, Brno, Czech
Republic
Year: 2002
Nominal Power: 200 kW at 53.5 m head and 400
l/s flow
Controls:
Type: Simatic 7 PLC
Plant Capacity:
Gross Head: 53,5 m
Design Flow: 600 l/s
Nominal Capacity: 300 kW
Annual Production: 1.200.000 kWh
Full Load Operation: 4.140 hours per year
Tailwater Conduit:
Cross Section: trapezoidal channel, partly piped
Length: 300 m